[Skip to Content]
Provided by ASME The American Society of Mechanical Engineers
Banner
PVP 2027
Location: Marriott Rive Gauche
Paris, France

Conference: July 25–July 30, 2027
Exhibition: July 26–July 27, 2027
Menu
  • Home
  • My Account
  • Event Site
  • Policies
    • Conflict in Ukraine
    • Presentation Requirements
    • Confirm Co-Authorship
    • Code of Conduct/Anti-Harassment
    • Artificial Intelligence
    • The Role of the Corresponding Author
  • Help
    • Contact Us
    • Author Resources
      • ASME Presenter Attendance Policy
      • ASME Plagiarism Screening (iThenticate)
      • Full-length Paper Preparation
      • Conference-Specific Information and Templates
      • Copyright Transfer Form
      • Technical Presentation Tips
      • Indexing
      • Author FAQS
      • Submission Types
    • Help Desk Calls
    • Webtool Feedback And Feature Requests
    • Organizer Resources
  • Home
  • ASME 2021 Pressure Vessels & Piping Conference (PVP2021) Session Gallery
  • OAC-06-01 Operation and Maintenance of Pressure Vessels, Heat Exchangers, Piping and Supports
  • Structural Integrity Assessment of Refractory Lined Component With Thermal Hot Spot Subjected to Steam Cooling

Session: OAC-06-01 Operation and Maintenance of Pressure Vessels, Heat Exchangers, Piping and Supports

Paper Number: 61077

Start Time: Wednesday, July 14, 2021, 09:00 AM

61077 - Structural Integrity Assessment of Refractory Lined Component With Thermal Hot Spot Subjected to Steam Cooling 

The refractory lined components could be damaged during operation due to various causes such as thermal expansion and contraction from changes of the temperature in service fluids, vibration caused by internal flow, or improper refractory construction. The damaged refractory causes thermal hot spot because a hot service fluid contacts to the inside surface of the component directly and this situation leads temperature increases in the skin of the component. This temperature increases from thermal hot spot does not causes immediate failure of the component, but creep phenomenon can causes structural rupture in the long term. As one of the countermeasures against thermal hot spot, the steam cooling is used as a field practice of maintenance works to reduce elevated temperature by spraying steam onto the area of thermal hot spot. However, when steam cooling is applied, it is designed and installed based on experiences without performing proper engineering. After steam cooling is applied, it is observed that thermal hot spot is locally cooled only in the area where the steam touches, which also raises concerns about unexpected damage due to local thermal gradient from localized cooling. This paper provides the evaluation of structural integrity of an actual case of thermal hot spot subjected to steam cooling in the FCC unit and discusses the appropriate steam cooling method as a countermeasure for thermal hot spot to ensure more effective structural integrity.

Presenting Author: Capjoo Choi GS Engineering & Construction

Authors:

Eui Jong Yoo GS Caltex Coporation
Capjoo Choi GS Engineering & Construction

Structural Integrity Assessment of Refractory Lined Component With Thermal Hot Spot Subjected to Steam Cooling

Category

Technical Paper Publication

This site supports all modern browsers, such as Chrome, Firefox, Safari, and Edge. Microsoft has announced it will no longer support IE 11 as of August 2021. If you prefer to or you are required to continue using a Microsoft browser, you can use Edge.

  • ASME.ORG
  • Press
  • Terms of Use
  • Privacy Statement
  • ASME Communication Preferences
  • Community Rules

© The American Society of Mechanical Engineers

Stay Connected